Start Time : 2016-03-05 14:34:36 End Time : 2016-03-05 14:46:28
Total number of Events : 584658 initialied beam energy : 2.093GeV
Magnet Current : 3369.4572A Lum(Begin Run) : 8364.822 Lum(End Run) : 8365.104
Run Task : 4180 beam type : collision
HIT_MAP : Normal
HV : Abnormal
MUON : trip
Other Problems : NO
Other comment : we lost the e+ beam which triggered the trip on the MU HV system. ----2016-03-05 14:50:14
Shift Chief : Hajime 2016-03-05 14:50:14