RUN STATUS

Run Number : 86887     Status : Good 

Start Time : 2025-07-22 23:28:09    End Time : 2025-07-22 23:50:04

Total number of Events : 1344679     initialied beam energy : 1.85822GeV

Magnet Current : 3369.5005A     Lum(Begin Run) : 37587.293     Lum(End Run) : 37587.531

Run Task : psi(2s)     beam type : collision

HIT_MAP : Normal

HV : Abnormal
      MDC : MDC, CGEM, ETOF, BTOF, MUON HV all trip, stopped run
      MUON : MDC, CGEM, ETOF, BTOF, MUON HV all trip, stopped run
      TOF : MDC, CGEM, ETOF, BTOF, MUON HV all trip, stopped run

Other Problems : NO

Other comment : electron beam loss led to HV trip of MDC, CGEM, ETOF, BTOF, MUON, stopped run. ----2025-07-22 23:56:11

Shift Chief : Saskia Plura    2025-07-22 23:56:11